1/2″ 3/4″ 1″ 304 Stainless Steel Motorized Ball Valve 220VAC 12VDC 24VDC 24VAC 3-Wire 2 Control Brass Electric Ball Valve
$92.13 – $215.01
Description
- Structure: Ball
- Origin: Mainland China
Specification
Medium: Cold/hot water, 60% Ethylene Glycol
Material: Stainless Steel
Power Supply: AC220V/DC12V/DC24V
Structure Forms: Two Ways,
Operation Mode: Three Wire Two Ways Control
Power: 6W (Only when the valves open and close)
Running Time: 5-15 Seconds
Nominal Pressure: 1.6MPa
Medium Temperature: 2°~95°
Maximum Differential Pressure: 1.0MPa
Connection Mode: G Internal Thread
Torque:220V 8 N.M, DC12/24V 6 N.M
Waterproof level:IP65
Package list: 1PC* Ball Valve
CR02: 3-wire, (three-wire two-control mode) wiring diagram
Voltage: AC220V, DC12V, DC24V
1. The SW is connected with OPEN, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve remains in the open state.
2. The SW is connected with CLOSE, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in the closed state.
CR03: 3-wire, (three-wire one control mode) wiring diagram
Voltage: AC220V,
Remarks: If the power supply is a DC power supply, the red wire needs to be connected to the positive pole, and the green wire needs to be connected to the negative pole.
1. The SW is closed, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve is kept in a fully closed state.
2. The SW is disconnected, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in a fully closed state.
CR04: 2-wire, (power-off reset mode) wiring diagram
Voltage: DC12V, DC24V, AC220V,
Remarks: POWER is an outside connect working power supply, and a farad capacitor is used internally as a backup power supply. The charging time is fast, and it can work in occasions with high switching frequency.
1. SW is connected with OPEN, the valve is opened, and the internal power is automatically cut off when it is in place, and the valve remains in the open state.
2. The SW is connected with CLOSE, the valve is closed, and the internal power is automatically cut off when it is in place, and the valve is kept in the closed state.