Rising Stem Gate Valve

Water Ball Valve

Water Bypass Valve

water heater expansion valve

flanged ball valve

Water Tank Valve

Lv Guocheng, Xu Chunchun, Cheng Haidong
(School of Materials SClence and Engineering, Beijing University of Chemical Technology, Beijing 100029, China)

Abstract: The relationship between the stress corrosion susceptibility of 304 stainless steel and the concentration of Cl in the solution was obtained by slow tensile experiment, and the fracture morphology of the tensile specimen was analyzed by scanning electron microscope. The fracture morphology of the tensile specimen was analyzed by scanning electron microscope, and the critical chloride ion concentration for stress corrosion of 304 stainless steel was obtained. The use of self-designed A self-designed device was used to apply tensile stress to the 304 stainless steel specimen, and electrochemical in situ testing under constant strain conditions was used to study the rupture potential of the passivation film of 304 stainless steel. Stainless steel passivation film rupture potential and chloride ion concentration of the relationship. The relationship between the Cl- concentration leading to the sudden change of rupture potential of passivation film and the critical Cl concentration for stress corrosion rupture was found to be the same as that of the rupture potential. It was concluded that the Cl- concentration leading to the rupture potential of the passivation film and the critical Cl- concentration for stress corrosion rupture are basically the same.

Keywords: 304 stainless steel; passivation film; stress corrosion; critical chloride ion concentration
Classification number: TG172.6 Document identification code: A Article number: 1000-6613 (2008) 08-1284-04

1 Introduction 304 Stainless Steel

304 stainless steel has been widely used because of its good corrosion resistance. However, under the action of chloride ions, 304 stainless steel will undergo stress corrosion rupture [1-2], resulting in equipment running, bubbling, dripping, and leaking, which often brings disastrous consequences. Moreover, the equipment in the cold Moreover, the chlorine ions in the medium such as cooling water in the equipment will be gradually concentrated, increasing the corrosion of the equipment. A large number of scientific research work reveals the occurrence and development of stress corrosion[4-6]. Stress corrosion of stainless steel is related to Cl- concentration, temperature, pH value, and other ions in solution 7, when the Cl- concentration reaches the critical value, the stress corrosion of stainless steel is related to Cl- concentration, temperature, pH value, and other ions in solution [7]. Cl- concentration reaches a critical value, 304 stainless steel will occur stress corrosion rupture, but the critical value did not reach a unanimous conclusion [8-10], and can not be proposed to completely avoid or eliminate stress corrosion. Can not be proposed to completely avoid or eliminate the boundary conditions of stress corrosion.

In certain conditions of stainless steel passivation film rupture formed by etching holes often become a source of stress corrosion, so the structure and performance of the passivation film affect the corrosion resistance of stainless steel. The corrosion resistance of the stainless steel passivation film is largely determined by the rupture of the metal in the medium of the film. potential [12]. Therefore, the study of 304 stainless steel passivation film rupture potential Eo, can reflect the stability of the stainless steel passivation film, and further study the stress corrosion behavior of 304 stainless steel.

In this paper, the critical Cl- concentration of 304 stainless steel for stress corrosion was obtained by slow tensile experiment and corresponding fracture analysis; in-situ electrochemical analysis under constant deformation was used to study the stress corrosion behavior of 304 stainless steel. In this paper, the critical Cl- concentration of 304 stainless steel for stress corrosion was obtained by slow tensile test and corresponding fracture analysis; the relationship between the rupture potential of 304 stainless steel passivation film and the Cl- concentration was investigated by in-situ electrochemical test under constant deformation. The stress corrosion mechanism of 304 stainless steel in Cl- containing media was further analyzed.

2 Experimental Method

The experimental material is 304 stainless steel sheet, composition (mass fraction): Cr 17.080%, Ni8.010%, Mn 1.380%, Si 0.490%, C 0.050%, S 0.001%, P 0.020%, the remaining Fe.
Si 0.490%, C 0.050%, S 0.001%, P 0.020%, and the rest is Fe. All the specimens in this study were subjected to high-temperature solid solution treatment (1050 ℃, 0.020%).
treatment (1050 ℃, 30 min, water cooling). The surfaces of the specimen were polished with water sandpaper, degreased with acetone, rinsed with deionized water, and dried. Rinse with deionized water, dry and spare. Different concentrations of NaCl solutions were prepared with deionized water and analytically pure NaCl, and the pH value was adjusted to 7°C with NaOH or HCl solution. The pH value was adjusted to 7±0.1 with NaOH or HCl solution. The test temperature was 60±0.1℃.

2.1 Slow Strain Rate Method

The slow tensile test was performed using a dumbbell-type specimen with a spacing section of (20mm×3mm×2mm). The slow tensile experiments were carried out athlete 10 kN stress corrosion testing machine, tensile strain rate 2 × 10⁶s’.

2.2 Fracture Analysis Of Slow Tensile Specimen

After the specimen fracture, remove it immediately and protect the fracture. The corrosion products adhered to the surface were first rinsed with deionized water and then blown dry with nitrogen. Blow dry. In the ultrasonic cleaner using acetone to clean the fracture, nitrogen blow-drying using Cambridge-S250 scanning electron microscope to observe the fracture morphology. The fracture morphology was observed using a Cambridge-S250 scanning electron microscope.

2.3 In-Situ Electrochemical Testing At Constant Strain

In order to study the effect of Cl concentration on the surface passivation film of 304 stainless steel under tensile stress, an in-situ electrochemical test setup under constant strain was designed. The in situ electrochemical testing device was designed under constant strain, see Fig. 1. It is known from the pre-test that when the strain is greater than 30%, the increase of strain has less effect on the rupture potential of the passivation film. Therefore, a strain of 30% was used in this study.

The electrochemical test specimen was of dumbbell type, and the dimension of the spacing part was (20mm×2mm×2mm). The self-designed device shown in Fig. 1 was used to apply tensile stress to the specimen. The tensile stress was applied to the specimen with 30% deformation (without unloading) using the self-designed device shown in Fig. 1. The center portion of the specimen was left bare for 1 cm² and the rest of the specimen was sealed with silicone rubber adhesive. The rest of the specimen was sealed with a silicone rubber adhesive.

The electrochemical tests were carried out using a three-electrode system, with the specimen as the study electrode, a platinum electrode as the auxiliary electrode, and a saturated calomel electrode as the reference electrode. The scanning speed of the kinetic potential was 20 mV/min.

fig. 1 constant strain in situ electrochemical test setup
fig. 1 constant strain in situ electrochemical test setup
  1. reference electrode 2. working electrode 3. auxiliary electrode 4. pin 5. dumbbell specimen 6. screw 7. electrochemical workstation 8. silicon rubber 9. solution

3 Results and Discussion

3.1 The Effect Of Changes In Cl- Concentration On The Stress Corrosion Susceptibility Of 304 Stainless Steel

Table 1 for the specimen in the solution containing different Cl- concentrations of slow strain tensile test obtained test data. Elongation is the specimen Elongation is the ratio of the elongation between the specimen markings and the original markings after pulling off, and the elongation of the specimen tensile in air and solution is δ. and δ. The test measured that the 8.5 mm of 304 stainless steel is the same as the original specimen. 8. 304 stainless steel was measured as 71.44%. The plasticity loss lδ was used as a characterization parameter for the stress corrosion susceptibility of the material[13], the i.e.

equal
equal

The values of lδ for specimens stretched in different concentrations of Cl- solutions are shown in Table 1

table1
Table 1 Effect of chloride ion concentration on stress corrosion susceptibility

Figure 2 shows the relationship of lδ to Cl- concentration.
As can be seen from the figure, when the Cl- concentration is less than 90 mg/L, with the increase of Cl- concentration, the stress corrosion susceptibility increases significantly; when the Cl- concentration is greater than 90 mg/L, the stress corrosion susceptibility is larger but changes slowly. Curve turns at point g, so this point is the stress corrosion sensitivity with the Cl- concentration of the mutation point, that is, the critical Cl- concentration of stress corrosion occurs.

fig2
Figure 2 shows the relationship of lδ to Cl concentration. Chloride ion concentration/mg.L-1

Figure 3 shows the SEM morphology of the fracture of 304 stainless steel after slow stretching in Cl- concentrations of 60 mg/L, 90 mg/L, 300 mg/L, and 900 mg/L solutions.
As can be seen in Fig. 3, when the Cl- concentration is 60 mg/L, there are a large number of tough nests on the fracture surface, which is a typical tough fracture morphology, see Fig. 3 (c); when the Cl- concentration is 90 mg/L, there are a large number of tough nests on the fracture surface. When the Cl concentration was 90 mg/L, small secondary cracks began to appear on the fracture surface, but the number was very small, see Fig. 3 (b); when the Cl- concentration was 300 mg/L, the size and number of secondary cracks on the fracture surface increased significantly compared with Fig. 3 (b), see Fig. 3 (c); when the Cl- concentration was 900 mg/L, the size and number of secondary cracks on the fracture surface increased significantly compared with Fig. 3 (c); and when the Cl- concentration was 900 mg/L, the size and number of secondary cracks on the fracture surface increased significantly. When the Cl- concentration was 900 mg/L, the number of secondary cracks on the fracture surface increased compared with Fig. 3(c). The number of secondary cracks on the fracture surface increased at a Cl- concentration of 900 mg/L compared with that in Fig. 3(c), but the change in crack size was not significant, see Fig. 3(d).

fig3
Fig. 3 Fracture morphology (SEM) of tensile specimens in different Cl- concentrations.

From Fig. 2 and Fig. 3, it can be seen that 90 mg/L is the mutation point of stress corrosion sensitivity with the change of Cl- concentration, i.e., 90 mg/L is the critical Cl- concentration for the occurrence of stress corrosion under the test conditions. When the Cl- concentration is greater than or equal to this value, secondary cracks will appear on the fracture surface, and stress corrosion will occur; when the Cl- concentration is less than 90 mg/L, there are no secondary cracks on the fracture surface, and the stress corrosion sensitivity is small.

3.2 Effect Of Cl- Concentration On Rupture Potential Of 304 Stainless Steel Passivation Film Under Tensile Stress

Figure 4 shows the anodic polarization curves of specimens with 30% strain in different concentrations of Cl- solution. The corrosion current density is very small in the passivation zone, about 2 μA/cm² (known from experimental data), and the passivation film shows good protection. When the potential exceeds the rupture potential of the passivation film, the corrosion current density increases rapidly, 304 stainless steel was severely corroded. Therefore, the rupture potential of the passivation film is a very important parameter that can be used to evaluate the stability of the passivation film in solution. The more positive the rupture potential, the more stable the passivation film; the more negative the rupture potential, the less stable the passivation film. Corrosion current density of 10 μA/cm² when the corresponding potential for the passivation film rupture potential Eb[14], that is, Figure 4, the potential of each curve at the turn.
As can be seen from Fig. 4, with the increase of Cl- concentration in the solution, the width of the passivation zone of 304 stainless steel becomes narrower, and the rupture potential of the passivation film becomes negative. potential becomes negative. It shows that the Cl- concentration has a significant effect on the corrosion of 304 stainless steel under tensile stress.

fig.4
Fig 4. Potential Escc/V Fig 5. Chloride ion concentration/mg.L-1

Figure 5 shows the rupture potential of the passivation film of 304 stainless steel in different concentrations of Cl- solution versus Cl- concentration. In the Cl- concentration is low, the passivation membrane ruptures potential E. With the increase of Cl- concentration quickly negative shift, and linear relationship; when the Cl- concentration is large, the passivation membrane ruptures potential E, with the increase of Cl- concentration slowly negative shift, also a linear relationship, the two straight lines intersected at point F (98 mg/L, 266 The two lines intersect at point F (98 mg/L, 266 mV). That is, when the Cl- concentration is greater than 100 mg / L, the rupture potential of the passivation membrane is more negative, and the change is not large, indicating that the passivation membrane has been damaged, increasing the concentration of Cl-, the impact has been small; when the Cl- concentration of less than 100mg/L, with the decrease in the concentration of Cl-, the rupture potential is rapidly positively shifted, that is, the passivation membrane of the protection of the rapid increase. Therefore, it can be considered, bear 30% of the tensile strain of 304 stainless steel in less than 100 mg/L of Cl- solution, has a better stress corrosion resistance. This is consistent with the critical Cl-concentration that leads to stress corrosion rupture of 304 stainless steel is consistent.
The mechanism of stress corrosion rupture in which anodic dissolution plays a controlling role has been extensively studied, but controversial. Many have suggested that the corrosion process promotes localized plasticity. that the corrosion process promotes localized plastic deformation leading to stress corrosion rupture of the material [15-18]. In this paper, we derived the results leading to the rupture of the passivation film The agreement between the Cl-concentration that leads to the potential mutation and the critical Cl- concentration for the occurrence of stress corrosion rupture in this paper suggests that the rupture of the passivation film plays a significant role in the stress corrosion of 304 stainless steel. steel plays an important role in stress corrosion. After the rupture of the film, localized anodic dissolution results in the formation of weak structures such as pitting corrosion.1191 Stress corrosion forms nuclei in the weak zones. Stress corrosion nucleates and expands in the weak zone.

4 Conclusion

(1) The critical- concentration for stress corrosion of 304 stainless steel in a neutral solution at 60℃ is about 90mg/L. The Cl- concentration of 304 stainless steel in a neutral solution at 60℃ is about 90 mg/L.
(2) The constant strain in-situ electrochemical testing method can quickly measure the sudden change of Cl- concentration that leads to the rupture potential of the membrane, and thus we can Preliminary judgment of the possibility of stress corrosion rupture of 304 stainless steel.

References

[1] Osama M Alyousif, Rokuro Nishimura. The stress corrosion cracking behavior of austenitic stainless steels in boiling magnesium chloride solutions[J]. Corrosion Science,
2007, 49: 3040-3051.
[2] Katsumi Yamamoto, Keizo Hosoya. Corrosivity of Br – and C1 – on duplex stainless steel[J]. Materials Science and Engineering, 1995, 1 98: 239-243.
[3]苟晓东,黄种买,虞启义,等,城市二级污水回用作电厂循环冷却水铜管腐蚀研究[J],化工进展,
2004, 23 (3) : 304- 306.
[4] Masayuki Kamaya , Takumi Haruna. Influence of local stress on initiation behavior of
stress corrosion cracking for sensitized 304 stainless steel[J]. Corrosion Science, 2007, 49(8): 3303-3324.
[5] Osama M Alyousif, Rokuro Nishimura. The effect of test temperature on SCC behavior of austenitic stainless steels in boiling saturated magnesium chloride solution[J]. Corrosion Science, 2006, 48(1 2): 4283-4293.
[6] Monika Gomez-Duran, Digby D. Macdonald Stress corrosion cracking of sensitized type 304 stainless steel in thiosulphate solution (II). Dynamics of fracture[J]. Corrosion Science, 2006, 48(7): 1 608-1622.
[7] Rokuro Nishimura. Characterization and perspective of stress corrosion cracking of
austenitic stainless steels (type 304 and type 316)in acid solutions using constant load
method[J]. Corrosion Science, 2007, 49(1 ): 81 -91.
[8] Rokuro Nishimura, Yasuaki Maeda.Stress corrosion cracking of type 304 austenitic
stainless steel in sulphuric acid solution including sodium chloride and chromate[J]. Corrosion Science, 2004, 46(2): 343-360.
[9] Rokuro Nishimura. The effect of chloride ions on stress corrosion cracking of type 304
and type 316 austenitic stainless steels in sulfuric acid solution[J]. Corrosion Science, 1993, 34(11): 1859-1868.